INSTALLATION INSTRUCTIONS
Power Adaptor Kit
Model 1092-07
The Model 1092 Power Adaptor Kit permits the connection of a three-tab radio
control receiver to a garage door operator which does not conform to the three-
terminal standard adopted by DORCMA. The operator may have only two terminals
or the numbering sequence may be different.
TO CONNECT A THREE-TAB RECEIVER:
1. The push on receptacle on each wire is connected to the straight tab of the
receiver terminals.
2. Each terminal is marked on the data label on the back of the receiver.
Connect the wires to the receiver terminals as follows:
a. Receptacle with two wires (power transformer and
push button wire) to terminal mark “1” or “24V”.
b. Receptacle with second push button wire to terminal
marked “2” or “relay”.
c. Receptacle with remaining transformer wire to
terminal marked “3” or “radio power”.
3. Connect the two spade lugs to the wall button terminals on the operator
(terminals 1 and 2 on a three terminal operator). Plug the transformer into a 115
VAC outlet.
LINEAR CORPORATION
2055 Corte Del Nogal
Carlsbad, California 92009
Copyright © 1999 Linear Corporation
216720 A
|
Motorola i875 User Manual
Motorola C330 User Manual
Maxtor STM3250820AS User Manual
Maxtor DIAMONDMAXTMPLUS6800 90683U2 User Manual
Lindy 32870 User Manual
Lennox Hearth S1300 User Manual
Kenwood DPF 2030 User Manual
Kaser Computer Drive User Manual
JVC LVT1848 001C User Manual
Compaq SDLT 110 User Manual